151 research outputs found

    Erratum to: ‘Early prediction of acute kidney injury after transapical and transaortic aortic valve implantation with urinary G1 cell cycle arrest biomarkers’

    Get PDF
    Background: Acute kidney injury (AKI) is a common complication following transcatheter aortic valve implantation (TAVI) leading to increased mortality and morbidity. Urinary G1 cell cycle arrest proteins TIMP-2 and IGFBP7 have recently been suggested as sensitive biomarkers for early detection of AKI in critically ill patients. However, the precise role of urinary TIMP-2 and IGFBP7 in patients undergoing TAVI is unknown. Methods: In a prospective observational trial, 40 patients undergoing TAVI (either transaortic or transapical) were enrolled. Serial measurements of TIMP-2 and IGFBP7 were performed in the early post interventional course. The primary clinical endpoint was the occurrence of AKI stage 2/3 according to the KDIGO classification. Results: Now we show, that ROC analyses of [TIMP-2]*[IGFBP7] on day one after TAVI reveals a sensitivity of 100 % and a specificity of 90 % for predicting AKI 2/3 (AUC 0.971, 95 % CI 0.914-1.0, SE 0.0299, p = 0.001, cut-off 1.03). In contrast, preoperative and postoperative serum creatinine levels as well as glomerular filtration rate (GFR) and perioperative change in GFR did not show any association with the development of AKI. Furthermore, [TIMP2]*[IGFBP7] remained stable in patients with AKI = 1, but its levels increased significantly as early as 24 h after TAVI in patients who developed AKI 2/3 in the further course (4.77 +/- 3.21 vs. 0.48 +/- 0.68, p = 0.022). Mean patients age was 81.2 +/- 5.6 years, 16 patients were male (40.0 %). 35 patients underwent transapical and five patients transaortic TAVI. 15 patients (37.5 %) developed any kind of AKI;eight patients (20 %) met the primary endpoint and seven patients required renal replacement therapy (RRT) within 72 h after surgery. Conclusion: Early elevation of urinary cell cycle arrest biomarkers after TAVI is associated with the development of postoperative AKI. [TIMP-2]*[ IGFBP7] provides an excellent diagnostic accuracy in the prediction of AKI that is superior to that of serum creatinine

    Valve hemodynamic performance and myocardial strain after implantation of a third-generation, balloon-expandable, transcatheter aortic valve

    Get PDF
    Background: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS); however, transcatheter aortic valve implantation (TAVI) may positively affect LV mechanics. Assessed herein is the performance of the SAPIEN 3 transcatheter heart valve (THV) and the effect of TAVI on LV function recovery, as assessed by global longitudinal strain (GLS). Methods: A subset of patients from the SOURCE 3 registry (n = 276) from 16 European centers received SAPIEN 3 balloon-expandable THV. Echocardiography was performed at baseline, postprocedure, and at 1 year, including assessment of GLS using standard two-dimensional images, and was analyzed in a core laboratory. Paired analyses between baseline and discharge, baseline and at 1 year were conducted. Results: Hemodynamic parameters were improved after TAVI and sustained to 1 year. At 1 year, the rate of moderate to severe paravalvular leaks (PVL), and moderate to severe mitral and tricuspid regurgitations were 1.8%, 1.7%, and 8.0%, respectively. The discharge GLS (–15.6 ± 5.1; p = 0.004; n = 149) improved significantly from baseline (–15.1 ± 4.8) following TAVI. This improvement was sustained at 1 year compared with baseline (–17.0 ± 4.6, p < 0.001; n = 100). Conversely, LV ejection fraction (LVEF) did not significantly change following TAVI (p = 0.47). Conclusions: Following TAVI with a third-generation THV, valve performances were good at 1 year with low PVL rate. The LV mechanics improved immediately after the procedure and were maintained at 1 year. These findings demonstrate the benefit of TAVI on LV mechanics, and suggests that GLS may be superior to LVEF in assessing this benefit. Clinicaltrial.gov number: NCT0269895

    Safety Evaluation of a Medical Congress Held During the COVID-19 Pandemic-A Prospective Cohort

    Full text link
    Objectives: During the COVID-19 pandemic, few scientific congresses have been held on-site. We prospectively evaluated the safety concept of the congress of the Swiss Societies of Infectious Diseases and Hospital Hygiene. Methods: The congress was held in Geneva (Switzerland) while local COVID-19 incidence (with SARS-CoV-2 wild type circulating) was 65/100,000 population (September 2020). A rigorous safety concept was implemented. Congress attendees filled out a questionnaire to assess risk perception, exposures, symptoms and diagnoses of SARS-CoV-2 before, during and after the congress. Dried blood spots were taken on-site and 4 weeks later to detect SARS-CoV-2 seroconversions. Results: Of 365 congress attendees, 196 (54%) either answered the questionnaire (N = 150) or provided baseline and follow-up blood samples (N = 168). None of the participants reported a positive PCR in the 2 weeks after the congress. Five of 168 (3%) participants were seropositive at follow-up, all of which had already been positive at baseline. Conclusion: Findings indicate that congresses with a rigorous safety concept may take place, even in areas with moderately-high COVID-19 activity. Whether this holds true in vaccinated populations and with more transmissible viral variants circulating remains unclear

    Применение активной молниезащиты, как способ повышения уровня безопасности промышленной площадки

    Get PDF
    В данной работе автором проводится разработка инженерно-технических мероприятий направленных на повышение уровня безопасности промышленной площадки эксплуатирующей природный газ действующего производства города Томск.In the paper author presents the development of measures aimed at the improving safety level of the Tomsk ongoing production gas operating industrial site

    Characterization of Total RNA, CD44, FASN, and PTEN mRNAs from Extracellular Vesicles as Biomarkers in Gastric Cancer Patients

    Get PDF
    In-depth characterization has introduced new molecular subtypes of gastric cancer (GC). To identify these, new approaches and techniques are required. Liquid biopsies are trendsetting and provide an easy and feasible method to identify and to monitor GC patients. In a prospective cohort of 87 GC patients, extracellular vesicles (EVs) were isolated from 250 µL of plasma. The total RNA was isolated with TRIZOL. The total RNA amount and the relative mRNA levels of CD44, PTEN, and FASN were measured by qRT-PCR. The isolation of EVs and their contained mRNA was possible in all 87 samples investigated. The relative mRNA levels of PTEN were higher in patients already treated by chemotherapy than in chemo-naïve patients. In patients who had undergone neoadjuvant chemotherapy followed by gastrectomy, a decrease in the total RNA amount was observed after neoadjuvant chemotherapy and gastrectomy, while FASN and CD44 mRNA levels decreased only after gastrectomy. The amount of RNA and the relative mRNA levels of FASN and CD44 in EVs were affected more significantly by chemotherapy and gastrectomy than by chemotherapy alone. Therefore, they are a potential biomarker for monitoring treatment response. Future analyses are needed to identify GC-specific key RNAs in EVs, which could be used for the diagnosis of gastric cancer patients in order to determine their molecular subtype and to accompany the therapeutic response

    Flattening the curve in 52 days: characterisation of the COVID-19 pandemic in the Principality of Liechtenstein - an observational study.

    Get PDF
    BACKGROUND The principality of Liechtenstein had its first COVID-19 case at the beginning of March 2020. After exponential growth, the pandemic’s first wave was contained, with the last case being diagnosed 52 days after the initial occurrence. AIM To characterise the COVID-19 pandemic in Liechtenstein. METHODS All patients diagnosed in Liechtenstein were followed up until recovery and again 6–8 weeks after symptom onset. They were contacted every 2 days to record their clinical status until the resolution of their symptoms. The diagnosis of COVID-19 was based on clinical symptoms and molecular testing. Household and close workplace contacts were included in the follow-up, which also comprised antibody testing. In addition, public health measures installed during the pandemic in Liechtenstein are summarised. RESULTS During the first wave, 5% of the population obtained a reverse transcriptase polymerase chain reaction test. A total of 95 patients (median age 39 years) were diagnosed with COVID-19 (82 who resided in Liechtenstein), resulting in an incidence in Liechtenstein of 0.211%. One patient, aged 94, died (mortality rate 1%). Only 62% of patients could retrospectively identify a potential source of infection. Testing the patients’ household and close workplace contacts (n = 170) with antibody tests revealed that 25% of those tested were additional COVID-19 cases, a quarter of whom were asymptomatic. Those households which adhered to strict isolation measures had a significantly lower rate of affected household members than those who didn’t follow such measures. The national public health measures never restricted free movement of residents. Masks were only mandatory in healthcare settings. The use of home working for the general workforce was promoted. Gatherings were prohibited. Schools, universities, certain public spaces (like sports facilities and playgrounds), childcare facilities, nonessential shops, restaurants and bars were closed. Social distancing, hygienic measures, solidarity and supporting individuals who were at risk were the main pillars of the public health campaigns. CONCLUSION The close collaboration of all relevant stakeholders allowed for the complete workup of all COVID-19 patients nationwide. A multitude of factors (e.g., young age of the patients, low-threshold access to testing, close monitoring of cases, high alertness and adherence to public health measures by the population) led to the early containment of the first wave of the pandemic, with a very low rate of serious outcomes. Antibody testing for SARS-CoV-2 revealed a substantial proportion of undiagnosed COVID-19 cases among close contacts of the patients

    Sensitivity of ICD coding for sepsis in children-a population-based study.

    Get PDF
    BACKGROUND International Classification of Diseases 10th edition (ICD-10) is widely used to describe the burden of disease. AIM To describe how well ICD-10 coding captures sepsis in children admitted to the hospital with blood culture-proven bacterial or fungal infection and systemic inflammatory response syndrome. METHODS Secondary analysis of a population-based, multicenter, prospective cohort study on children with blood culture-proven sepsis of nine tertiary pediatric hospitals in Switzerland. We compared the agreement of validated study data on sepsis criteria with ICD-10 coding abstraction obtained at the participating hospitals. RESULTS We analyzed 998 hospital admissions of children with blood culture-proven sepsis. The sensitivity of ICD-10 coding abstraction was 60% (95%-CI 57-63) for sepsis; 35% (95%-CI 31-39) for sepsis with organ dysfunction, using an explicit abstraction strategy; and 65% (95%-CI 61-69) using an implicit abstraction strategy. For septic shock, the sensitivity of ICD-10 coding abstraction was 43% (95%-CI 37-50). Agreement of ICD-10 coding abstraction with validated study data varied by the underlying infection type and disease severity (p < 0.05). The estimated national incidence of sepsis, inferred from ICD-10 coding abstraction, was 12.5 per 100,000 children (95%-CI 11.7-13.5) and 21.0 per 100,000 children (95%-CI 19.8-22.2) using validated study data. CONCLUSIONS In this population-based study, we found a poor representation of sepsis and sepsis with organ dysfunction by ICD-10 coding abstraction in children with blood culture-proven sepsis when compared against a prospective validated research dataset. Sepsis estimates in children based on ICD-10 coding may thus severely underestimate the true prevalence of the disease. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s44253-023-00006-1

    Sensitivity of ICD coding for sepsis in children-a population-based study

    Full text link
    BACKGROUND International Classification of Diseases 10th edition (ICD-10) is widely used to describe the burden of disease. AIM To describe how well ICD-10 coding captures sepsis in children admitted to the hospital with blood culture-proven bacterial or fungal infection and systemic inflammatory response syndrome. METHODS Secondary analysis of a population-based, multicenter, prospective cohort study on children with blood culture-proven sepsis of nine tertiary pediatric hospitals in Switzerland. We compared the agreement of validated study data on sepsis criteria with ICD-10 coding abstraction obtained at the participating hospitals. RESULTS We analyzed 998 hospital admissions of children with blood culture-proven sepsis. The sensitivity of ICD-10 coding abstraction was 60% (95%-CI 57-63) for sepsis; 35% (95%-CI 31-39) for sepsis with organ dysfunction, using an explicit abstraction strategy; and 65% (95%-CI 61-69) using an implicit abstraction strategy. For septic shock, the sensitivity of ICD-10 coding abstraction was 43% (95%-CI 37-50). Agreement of ICD-10 coding abstraction with validated study data varied by the underlying infection type and disease severity (p < 0.05). The estimated national incidence of sepsis, inferred from ICD-10 coding abstraction, was 12.5 per 100,000 children (95%-CI 11.7-13.5) and 21.0 per 100,000 children (95%-CI 19.8-22.2) using validated study data. CONCLUSIONS In this population-based study, we found a poor representation of sepsis and sepsis with organ dysfunction by ICD-10 coding abstraction in children with blood culture-proven sepsis when compared against a prospective validated research dataset. Sepsis estimates in children based on ICD-10 coding may thus severely underestimate the true prevalence of the disease. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s44253-023-00006-1

    Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis.</p> <p>Methods</p> <p>rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components.</p> <p>Results</p> <p>rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology.</p> <p>Conclusions</p> <p>Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.</p
    corecore